Live power & battery

The twelve live sensors poll the live_overview endpoint every 30 seconds. All use state_class: measurement, so Long-Term Statistics tracks hourly min/max/mean automatically.

Entity Key Unit
PV Power pv_power W
Battery Power battery_power W (± bidirectional)
Battery SoC battery_soc %
Grid Power grid_power W (± bidirectional)
Grid Import Power grid_consumption_power W (≥ 0)
Grid Export Power grid_feed_in_power W (≥ 0)
Total Consumption consumption_power W
Household Consumption household_power W
EV Charger Power ev_chargers_power W
Heat Pump Power heat_pumps_power W
AC Power acs_power W
Self-Sufficiency self_sufficiency %

Self-sufficiency trends

Drop the entity into a statistics-graph card, or build a Statistics Helper for rolling averages. No integration code needed.

Why grid_power is bidirectional

grid_power is the raw signed value from the inverter: positive on import, negative on export. The split grid_consumption_power / grid_feed_in_power channels are the ≥ 0 projections that back the *_energy counters and the Energy Dashboard wiring. Pick the one that matches your downstream consumer.

Battery sensors

  • battery_power is bidirectional (positive on discharge, negative on charge in the HA convention used by the Energy Dashboard). Not integrated into kWh directly — see Energy & cost for the split battery_charge_power_energy / battery_discharge_power_energy channels.
  • battery_soc is 0–100 %.