The twelve live sensors poll the live_overview endpoint every 30 seconds. All use state_class: measurement, so Long-Term Statistics tracks hourly min/max/mean automatically.
| Entity | Key | Unit |
|---|---|---|
| PV Power | pv_power |
W |
| Battery Power | battery_power |
W (± bidirectional) |
| Battery SoC | battery_soc |
% |
| Grid Power | grid_power |
W (± bidirectional) |
| Grid Import Power | grid_consumption_power |
W (≥ 0) |
| Grid Export Power | grid_feed_in_power |
W (≥ 0) |
| Total Consumption | consumption_power |
W |
| Household Consumption | household_power |
W |
| EV Charger Power | ev_chargers_power |
W |
| Heat Pump Power | heat_pumps_power |
W |
| AC Power | acs_power |
W |
| Self-Sufficiency | self_sufficiency |
% |
Self-sufficiency trends
Drop the entity into a statistics-graph card, or build a Statistics Helper for rolling averages. No integration code needed.
Why grid_power is bidirectional¶
grid_power is the raw signed value from the inverter: positive on import, negative on export. The split grid_consumption_power / grid_feed_in_power channels are the ≥ 0 projections that back the *_energy counters and the Energy Dashboard wiring. Pick the one that matches your downstream consumer.
Battery sensors¶
battery_poweris bidirectional (positive on discharge, negative on charge in the HA convention used by the Energy Dashboard). Not integrated into kWh directly — see Energy & cost for the splitbattery_charge_power_energy/battery_discharge_power_energychannels.battery_socis 0–100 %.- Hybrid-inverter installs (Sungrow, Enphase) carry both entities on the inverter sub-device. FoxESS and other PV-plus-battery-split installs get a separate
batterysub-device.